    Brand Name : BEITE
    Model Number : RP62 Series
    Certification : CE ISO
    Price : Negotiate
    Payment Terms : T/T, Western Union
    Supply Ability : 3000 Piece/Pieces per Month mini flow meter
    Delivery Time : 48H
    • Product Details
    • Company Profile

    Ultrasonic Liquid Level Meter With Multi-Pulse Low-Voltage Multi-Point Transmitting And Receiving Circuit

    Advanced Two-Wire Design for Industrial Automation with Ultrasonic Liquid Level Meter

    The two-wire ultrasonic level meter is an instrument used to measure the level of liquid or solid materials. It is usually used in industrial automation, material monitoring and environmental management. Its working principle is to use the time difference of ultrasonic wave propagation in the medium to determine the liquid level. The device calculates the height of the liquid or the accumulation height of the material by emitting ultrasonic signals and receiving reflected signals.


    Description


    Ultrasonic liquid level gauge is a digital liquid level instrument controlled by a microprocessor. In the measurement, the ultrasonic pulse is emitted by the sensor (transducer). The sound wave is reflected by the liquid surface and is received by the same sensor or ultrasonic receiver. It is converted into an electrical signal through a piezoelectric crystal or magnetostrictive device, and is transmitted and received by the sound wave. time to calculate the distance from the sensor to the surface of the liquid being measured. Due to the non-contact measurement, the measured medium is almost unlimited and can be widely used to measure the height of various liquid and solid materials.

    Multi-pulse low-voltage multi-point transmitting circuit, double-balanced noise suppression multi-point receiving circuit
    It improves the reliability of the instrument, solves the problem of inaccurate measurement of uneven material levels, and greatly enhances the anti-interference ability, allowing it to work stably near the transmission tower of the substation.
    Automatic power adjustment, gain control, temperature compensation.
    Yingling's detection technology and rich software functions are suitable for various complex environments.
    Waveform calculation technology improves the measurement accuracy of the instrument.
    The interference echo suppression function ensures the authenticity of the measurement data.
    16-bit D/A conversion improves the accuracy and resolution of current output.
    The sensor is made of tetrafluoroethylene material and can be used in various corrosive situations.
    Multiple output forms: programmable relay output, high-precision 4-20mA current output, Rs-485 digital communication output, split ultrasonic liquid level probe.


    Specification


    Main parameters of integrated ultrasonic liquid level meter​


    Measuring range0-3, 5, 8, 10, 15, 20, 30, 40, 50 100m
    Accuracy0.25%
    blind spot0.15-0.7m
    Operating temperature-20℃-+60℃
    pressure range-1-16kg
    power supply24VDC, 220VAC
    output4-20mA, Rs-485
    controlTwo-way relay
    Protection levelIP68
    Display method12864 dot LCD display

    Main parameters of corrosion-resistant sensor housing type split-type ultrasonic liquid level meter


    Measuring range0-3, 5, 8, 10, 15, 20m, 30, 40, 50, 60, 70m
    Accuracy0.25%
    blind spot0.15-1.2m
    Operating temperatureTransmitter-20℃-55℃ Sensor-25℃-80℃
    pressure range-1-16kg
    power supply24VDC, 220VAC
    output4-20mA, Rs-485
    controlFour way relay
    Protection levelIP68
    Display method12864-dot LCD display, corrosion-resistant sensor housing made of tetrafluoroethylene

    Technical indicators


    Measuring range0.3~5m, 0.3~8m, 0.5~12m
    blind spot<0.3m,<0.5 m
    launch angle12° Small display resolution: 1mm
    Accuracy±0.3%×range
    showFour digits and eight segments: 0.5-inch LED
    working frequency20 KHz ~ 43.0KHz (varies depending on model specifications)
    Site settingsCalibration is completed through the level meter button: factory calibration, can be calibrated on site
    Analog output signal4~20mA load>300Ω; 0~5V; 1~5V
    digital outputRS485 (supports Modbus) NPN switch output
    Operating VoltageDC12—24V power consumption<1.5W
    DimensionsΦ83×145×M65
    shell materialPP
    weight272g(5m); 410g(12m)
    Installation methodExternal straight pipe thread M65×1.5
    Protection levelIP65
    temperature-10℃~60℃

    Installation principle
    When the ultrasonic liquid level meter is working, high-frequency pulse sound waves are emitted by the transducer (probe) and are reflected by the surface of the measured object (water surface). The refracted reflected echo is received by the same transducer (probe) and converted into an electrical signal. . The time between pulse transmission and reception (the movement time of the sound wave) is proportional to the distance from the transducer to the object surface. The relationship between the sound wave transmission distance S, the sound speed C and the transmission time T can be expressed by the formula: S= CⅩT /2
    When installing an ultrasonic liquid level meter, the blind zone problem of the ultrasonic liquid level meter must be considered. When the liquid level enters the blind zone, the ultrasonic transmitter cannot measure the liquid level. Therefore, when determining the measuring range of the ultrasonic liquid level meter, a margin of 50 cm must be left. When installing, the transmitter probe must be higher than the maximum liquid level. The position is about 50 centimeters. Only in this way can the accurate monitoring of the liquid level and the safety of the ultrasonic liquid level meter be ensured.
    In actual use, due to poor installation considerations, the liquid level gauge was submerged in water, causing the liquid level gauge to be completely damaged.
    Features of SGM ultrasonic level meter
    Low price, small size and light weight, it can be used for non-contact level measurement of liquids and bulk solids in food, chemical, semiconductor and other industries, and can be used for remote level monitoring and pump control.
    Attention should be paid to mechanical installation: the installation should be perpendicular to the surface of the object to be measured, avoid being used to measure foam objects, and avoid being installed at a distance less than the blind zone distance from the surface of the measured object (blind zone: each product will have a standard, which will be known with the product) , it should be considered that the beam avoids blocking materials and does not meet the filling mouth and container wall. When detecting large solid objects, the probe orientation should be adjusted to reduce measurement errors.


    Catalog


    BTSL7100Ultrasonic level gauge
    modelAOne-piece two-wire system
    BIntegrated three-wire system
    CIntegrated four-wire system
    DSplit four-wire streamlined type
    ESplit four-wire standard type
    Range ratio4L=4m
    6L=6m
    8L=8m
    10L=10m
    12L=12m
    15L=15m
    20L=20m
    30L=30m
    40L=40m
    customL=…..m
    voltageDDC24V LCD liquid crystal display
    EDC24V LED digital tube display
    AAC220V LCD liquid crystal display
    Probe extension**mm

    Packing & Delivery
    Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

    FAQ
    1. Q: What information need to be provided to choose the suitable model?
    A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
    Flow range, Accuracy, Connection and other parameters.
    2. Q: Are you a trade company or a manufacturer?
    A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
    OEM & ODM service are available. Welcome to visit us in China.
    3. Q: What is your MOQ?
    A: To start our cooperation, sample order is acceptable.
    4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
    A: The delivery date is about 3-15 working days after receipt of payment.
    5. Q: What is your payment terms?
    A: We support T/T, PayPal ,Western Union.
    For mass production order, it is 30% deposit in advance and 70% balance before shipment.
    6. Q: Do you have a warranty for the Flow Meter?
    A: Yes, we have the warranty of 12 months.

    Quality Ultrasonic Liquid Level Meter With Multi-Pulse Low-Voltage Multi-Point Transmitting And Receiving Circuit for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Beite Smart Instrument Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)