Sign In | Join Free | My burrillandco.com
Home > Coriolis Force Mass Flowmeter >

Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry

    Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
     
    Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
    • Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
    • Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
    • Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
    • Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
    • Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers
    • Buy cheap Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry from wholesalers

    Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry

    Ask Lasest Price
    Brand Name : suzhou beite Smart Instrument Co., Ltd.
    Model Number : Coriolis Mass Flow Meter
    Certification : CE ISO
    Price : Negotiate
    Payment Terms : T/T, Western Union
    Supply Ability : 3000 Piece/Pieces per Month mini flow meter
    Delivery Time : 5 working days after payment
    • Product Details
    • Company Profile

    Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry

    Application
    The mass flow meter can be used in the following fields to meet the requirements of ingredient, mixing processes and commercial measurement.
    Chemical: containing chemical reaction system
    Petroleum: moisture content analysis
    Lipids: including vegetable oils, animal fats and other oils
    Pharmaceutical
    Painting
    Paper making
    Textile printing and dyeing
    Fuel: crude oil, heavy oil, coal slurry, lubricant and other fuels.
    Food: gas dissolving beverage, health drink and other liquid.
    Transportation: pipeline liquid measurement.
    Low temperature fluid, like liquid oxygen and liquid nitrogen, the low temperature up to -200℃
    High temperature fluid, the maximum temperature up to 300℃
    High pressure fluid, like slurry flow measurement for oil drilling cementing


    The selection of Coriolis Mass Flowmeter needs to be comprehensively considered according to the needs of the specific application environment, mainly including the following aspects:

    1. Measuring medium
    - **Medium type**: The measured fluid can be liquid, gas or mixture. Different media have different requirements for the sensor material and design of the flowmeter.
    - **Medium characteristics**: Including the viscosity, density, temperature, pressure and other characteristics of the medium. These parameters directly affect the accuracy and stability of the flowmeter.

    2. Flow range
    - According to the actual working conditions, determine the minimum, maximum and normal working flow range. The flowmeter range should cover all flow ranges under the working conditions, and try to make the normal operating flow within the optimal working range of the flowmeter.

    3. Pipe size
    - Select the appropriate flowmeter model according to the pipe diameter of the measured fluid. Usually, Coriolis mass flowmeters can measure fluids from very small pipe diameters to larger pipe diameters.

    4. Accuracy requirements
    - Different industries and applications have different accuracy requirements. Coriolis mass flowmeters generally have high measurement accuracy (usually up to ±0.1% to ±0.2%). If the application scenario has high requirements for accuracy, choose a high-precision model.

    5. Medium temperature and pressure
    - The sensor and transmitter materials of the Coriolis flowmeter need to be able to withstand the temperature and pressure of the working medium. Common high-temperature and high-pressure models are available.

    6. Material requirements
    - According to the corrosiveness or special requirements of the medium, select a suitable sensor material. Common materials include stainless steel, Hastelloy, titanium, etc., which are suitable for different corrosiveness and environments.

    7. Installation environment
    - The installation environment of the flowmeter is also an important consideration for selection, such as whether there is vibration, whether explosion-proof is required, protection level requirements, etc.

    8. Output signal
    - Confirm whether the output signal of the flowmeter meets the requirements of the control system. Common outputs include 4-20mA, voltage signal, pulse signal, HART, Modbus, etc.

    9. Price and brand
    - There are many brands of Coriolis mass flowmeters on the market, such as Emerson, KROHNE, Endress+Hauser, etc. When choosing, you need to combine the budget and the brand's technical support, after-sales service and other factors.

    10. Other special requirements
    - If there are other special process requirements, such as explosion-proof certification (such as ATEX, IECEx), hygiene standard certification (such as FDA, 3A standard), you need to consider them when selecting.

    Summary
    The selection of Coriolis mass flowmeter should be comprehensively analyzed based on multiple factors such as the measurement medium, flow range, accuracy requirements, installation environment, etc. to ensure that the selected model is suitable for the specific application scenario. It is recommended to communicate with suppliers or technical experts during the selection process to ensure that the most suitable product is selected.


    Detailed introduction of Coriolis mass flowmeter:

    The Coriolis Mass Flow Meter is a meter used to measure the mass flow of liquid or gas, and its working principle is based on the Coriolis effect. Coriolis flowmeters are widely used due to their high accuracy and wide range of applications. The following is a detailed introduction to the Coriolis mass flowmeter:

    Working Principle

    The working principle of the Coriolis mass flowmeter is based on the Coriolis Effect, which refers to the inertial force that an object will be subject to when it moves in a rotating system. Specifically, the Coriolis flowmeter uses the following steps to measure flow:

    1. **Fluid passing through the sensor**: The fluid flows in the sensor of the flowmeter, usually through a pair of vibrating tubes or vibrating elements.

    2. **Vibration of the vibrating tube**: The vibrating tubes of the flowmeter are forced to vibrate at a certain frequency and amplitude. The fluid exerts force on these vibrating tubes during the flow process.

    3. **Generation of Coriolis force**: When the fluid flows through the vibrating tube, Coriolis force is generated due to the inertia of the fluid, and this force causes the vibrating tube to have a relative displacement. This displacement affects the vibration frequency and phase of the vibrating tube.

    4. **Measurement and calculation**: The sensor detects the relative displacement and frequency change of the vibrating tube and converts these signals into mass flow values. By analyzing the vibration characteristics of the vibrating tube, the flow meter can directly calculate the mass flow of the fluid without considering the density and temperature changes of the fluid.

    Main features

    - **High accuracy**: Coriolis flowmeters provide very high measurement accuracy, which can reach 0.1% or even higher.

    - **Direct measurement of mass flow**: The mass flow of the fluid can be measured directly without converting the relationship between volume flow and density.

    - **Wide applicability**: Suitable for flow measurement of liquids and gases, including fluids with high viscosity, corrosiveness or high bubble content.

    - **Comprehensive functions**: In addition to flow measurement, many Coriolis flowmeters can also measure other parameters such as temperature, density and concentration.

    - **Less maintenance requirements**: Because the measuring part of the flowmeter has no moving mechanical parts, it is relatively less prone to wear and failure.

    Application areas

    - **Chemical industry**: Used to accurately measure the flow of chemicals, especially those that are highly corrosive or viscous.
    - **Food and Beverage Industry**: Accurately measure liquid raw materials and products to ensure product consistency and quality.
    - **Oil and Gas**: Measure the flow of oil, natural gas and their mixtures, especially in situations where high accuracy and stability are required.
    - **Pharmaceutical Industry**: Used to accurately measure the flow of drugs and other critical liquids during the production process.

    Overall, Coriolis mass flowmeters have become key flow measurement tools in many industrial fields due to their high accuracy, stability and versatility.


    Main Features
    1. Unchallengeable performance on liquid mass flow, volume flow, and density measurement
    2. Unique design delivers unparalleled measurement sensitivity and stability
    3. Guarantees consistent, reliable performance over the widest flow range
    4. Designed to minimize process, mounting, and environmental effect


    Working Principle
    If a pipe is rotated around a point (P) while liquid is flowing through it (toward or away from the center of rotation), that fluid will generate an inertial force, with reference to Figure 1.1:

    Sensor Structure

    Mass flow meter sensor consists of measurement tube, driving device, position detector, support structure, the temperature sensor, housing, etc.
    ① Supporting structure: the measuring tube fixed on the supporting structure as the vibrating axis.
    ② The measuring tube (Vibrating tube): consist of two parallel tubes.
    ③ Position detector: used for the measurement of measuring tube distortion.
    ④ Drive device: generate electromagnetic force to drive measuring tube to make it vibrate close to resonance frequency.
    ⑤ Housing: Protect the measuring tube, driving unit and detector.


    Technical Parameters

    SpecificationDN (mm)Flow range(kg/h)

    Zero Stability, kg/h


    Rated Pressure (MPa)

    NW

    (kg)

    GW

    (kg)

    0.2%0.15%0.1%
    DN330~96~1200.0180.0120.01240819
    DN660~540~6600.0990.0660.066201222
    DN880~960~12000.180.120.12201223
    DN10100~1500~18000.270.180.18201124
    DN15150~3000~42000.630.420.42201225
    DN20200~6000~78001.170.780.78162034
    DN25250~10200~135002.0251.351.35162135
    DN32320~18 000~24 0003.62.42.4162745
    DN40400~30 000~36 0005.43.63.6123555
    DN50500~48 000~60 000966124060
    DN80800~120 000~160 000241616890150
    DN1001000~222 000~270 00040.527278170245
    DN1501500~480 000~600 0009060606255350


    Packing & Delivery
    Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

    FAQ
    1. Q: What information need to be provided to choose the suitable model?
    A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
    Flow range, Accuracy, Connection and other parameters.
    2. Q: Are you a trade company or a manufacturer?
    A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
    OEM & ODM service are available. Welcome to visit us in China.
    3. Q: What is your MOQ?
    A: To start our cooperation, sample order is acceptable.
    4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
    A: The delivery date is about 3-15 working days after receipt of payment.
    5. Q: What is your payment terms?
    A: We support T/T, PayPal ,Western Union.
    For mass production order, it is 30% deposit in advance and 70% balance before shipment.
    6. Q: Do you have a warranty for the Flow Meter?
    A: Yes, we have the warranty of 12 months.

    Quality Accurate Coriolis Force Mass Flowmeter For Paper Making And Textile Industry for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Beite Smart Instrument Co., Ltd
    *Subject:
    *Message: